100 GHz DWDM Specifications | ||||
Channel Wavelength | Ref. ITU Grid | |||
Channel Spacing | 100 GHz (0.8nm) | |||
Channel Passband (nm) @ - 0.5dB | 0.3 | |||
Number of Channels | 2 | 4 | 8 | 16 |
Add/Drop Channel Insertion Loss (dB)* | < = 1.5 | < = 2.1 | <=3.0 | <=4.0 |
Express Channel Insertion Loss (dB)* | < = 0.7 | < = 1.2 | < = 2.5 | < = 3.5 |
Return Loss (dB) | > = 45 | |||
Adjacent Channel Isolation (dB) | > = 25 (DeMux) | |||
Non-adjacent Channel Isolation (dB) | > = 40 | |||
Wavelength Temperature Stability (nm/ ° C) | < = 0.002 | |||
Insertion Loss Thermal Stability dB/ ° C | < = 0.005 | |||
Channel Uniformity (dB) | < = 1.5 | |||
Polarization Dependent Loss (dB) | < = 0.2 | |||
Maximum Power Handling (mW) | 250 | |||
Operating Temperature ( ° C) | 0 to 65 | |||
Storage Temperature ( ° C) | -40 to 85 | |||
*Note: Insertion Loss values do not include connector losses. |
200 GHz DWDM Specifications | ||||
Channel Wavelength | Ref. ITU Grid | |||
Channel Spacing | 200 GHz (1.6nm) | |||
Channel Passband (nm) @ - 0.5dB | 0.6 | |||
Channel Number | 2 | 4 | 8 | 16 |
Add/Drop Channel Insertion Loss (dB)* | < = 1.5 | < = 2.1 | <=3.0 | <=4.0 |
Express Channel Insertion Loss (dB)* | < = 0.7 | < = 1.2 | < = 2.5 | < = 3.5 |
Return Loss (dB) | > = 45 | |||
Adjacent Channel Isolation (dB) | > = 25 (DeMux) | |||
Non-adjacent Channel Isolation (dB) | > = 40 | |||
Wavelength Temperature Stability (nm/ ° C) | < = 0.002 | |||
Insertion Loss Thermal Stability dB/ ° C | < = 0.005 | |||
Channel Uniformity (dB) | < = 1.5 | |||
Polarization Dependent Loss (dB) | < = 0.2 | |||
Maximum Power Handling (mW) | 250 | |||
Operating Temperature ( ° C) | 0 to 65 | |||
Storage Temperature ( ° C) | -40 to 85 | |||
*Note: Insertion Loss values do not include connector losses. |